Live status · Read the latest
monad-knowledge Wi-Fi sensing lab · FIIT STU
running csi-drift-real-floor simulation simulation

Link survival across surveyed furniture arrangements

In plain words

How do surveyed furniture arrangements change simulated link survival, and does a measured link failure have the same cause?

node node direct path reflected path low tables path changes and receiver failures need separate checks
A low table may leave the direct path clear. Other furniture and reflected paths still matter. The surveyed-scene study found link loss in some arrangements; a real outage needs an independent cause check. Schematic of the design, not a measurement.
Why it matters
The calibration model must distinguish a changed channel from a receiver that has stopped providing usable data.
How it is done
Compare paired links across separately staged surveyed arrangements and node-position perturbations, then inspect independent real link-state evidence.
Where it stands
Executed August 28: 12 simulations found 0/36, 3/36 and 5/36 lost links across three arrangements. The real amplitude comparison remains unread and the observed real outage is unattributed.

Asks, formallySurveyed furniture arrangements change link survival and surviving-link amplitude in the staged model. Test those predictions against independent real link-state evidence; an observed outage alone cannot identify furniture as its cause. The original near-flat prediction is retained below as a pre-execution hypothesis.

FoundSession 01M14FXTAQ9QA13GCDCN5DEA65 ran 12 simulations across three surveyed arrangements and four paired device-jitter seeds.

StandingCollecting data now · last activity 2026-08-28

Room`fiit-ground-0` (LiDAR-native FIIT library ground floor). Sensor arrangement `fiit-ground-fleet` — 10 surveyed nodes at z=90 cm, `monad01` transmitting, nine receivers, anchor fit 0.259 m RMS. Four scanned FURNITURE arrangements as the displacement states: `lidar-silent-2026-08-19` (31), `catalog-open-fill-2026-08-21` (15), `lidar-open-transfer-2026-08-21` (98), `lidar-tables-2026-08-28` (16).

The room

fiit · fiit-ground-0 · 10 devices

The floor this experiment runs on — its rooms, walls, furniture and the highlighted sensors placed for it. This is the surveyed layout as last exported; a run's replay below shows the geometry as it was simulated.

Link survival across surveyed furniture arrangements

Current assessment (2026-09-15)

Session 01M14FXTAQ9QA13GCDCN5DEA65 ran 12 simulations across three surveyed arrangements and four paired device-jitter seeds. Link losses were 0/36, 3/36 and 5/36. Surviving-link open-transfer minus tables amplitude was −4.530 dB, 95% CI [−10.92, +0.06]. One real receiver outage matched the signature, but furniture causation and the real amplitude arm remain unresolved.

The original 'not run' statement and near-flat prediction are superseded by the session. The arrangements describe different scanned zones, not a chronological furniture sequence. Tables below the antenna plane do not rule out all reflected-path effects. The excluded catalogue arrangement used default heights, and lost-link sentinels must not be averaged as physical amplitudes.

Next evidence needed: Link 01M14FXTAQ9QA13GCDCN5DEA65 to the comparison and preserve its unresolved real-data criteria. Separate acquisition failure from propagation change before using link loss to trigger recalibration.

Basis: Thesis Narrative, the September 10 synthesis, and the September 15 register review. See the review record for evidence sources and outstanding checks.

Earlier protocol and dated results

The methods and observations below retain their original scope. Read their readiness statements and proposed next steps as historical. The current assessment above records what has changed; frozen thresholds have not been retrospectively revised.

Original hypothesis (before this review): The synthetic drift curve built on a toy corridor makes a checkable prediction about the FIIT library: because every scanned table (59–75 cm) sits below every node antenna (90 cm), furniture displacement cannot reach the losin deep-blockage regime that was the only arm to move occupancy error. The sim run on the real floor should therefore predict a NEAR-FLAT drift curve. If EXP-F2's measured month shows drift anyway, the cause is not the layout, and the recalibration argument must move from geometry to hardware.

The prediction the geometry already forces

The newest scan gives sixteen tables at measured heights 59–75 cm. Every node antenna is at 90 cm. So no table in this room reaches the sensing plane, and the losin arm — the only arm in csi-layout-drift whose occupancy error moved — is geometrically unreachable by tables here.

The sim should therefore predict a near-flat drift curve on this floor. That is a falsifiable statement made in advance, and it is the opposite of the self-confirming pattern the 2026-06-24 rigor audit found across the sim corpus.

What a null means

If the simulated curve is flat and EXP-F2's measured month is flat, layout is not the drift axis in this room and ble-periodic-calibration needs a different mechanism. If the simulated curve is flat and the measurement drifts, the drift is not geometric — the standing alternative is thermal, and fleet_ops joins node temperature to CSI on (host, ts).

Either outcome is reportable. The outcome that would falsify the instrument rather than the hypothesis is a simulated curve that drifts steeply on furniture that cannot reach the antennas, which would say the scene staging is placing scatterers wrongly.

Explicit non-goals

  • This does not answer RQ4 on its own. It pairs a prediction with a measurement.
  • It does not use the impairment profile as validated. csi-impairment-fit runs first, or the sim's amplitude scale is a literature prior rather than this NIC's.
Campaigns & sessions 1 campaign instantiating this experiment
Campaign Session State Runs Started Report
c-csi-drift-real-floor CN5DEA65 finished 12 2026-08-28 synthesis →
Simulation runs the 12 most recent, newest first
Run Date Gate Campaign Replay
HB4A0RSD 2026-08-28 ✓ c-csi-drift-real-floor —
CDCA4K97 2026-08-28 ✓ c-csi-drift-real-floor —
4D82RX9V 2026-08-28 ✓ c-csi-drift-real-floor —
6D5X3S5V 2026-08-28 ✓ c-csi-drift-real-floor —
Q93WJN60 2026-08-28 ✓ c-csi-drift-real-floor —
J5M8SYM7 2026-08-28 ✓ c-csi-drift-real-floor —
MY43SRD4 2026-08-28 ✓ c-csi-drift-real-floor —
6Y5HNEWA 2026-08-28 ✓ c-csi-drift-real-floor —
F4B1QQXF 2026-08-28 ✓ c-csi-drift-real-floor —
ACH007XH 2026-08-28 ✓ c-csi-drift-real-floor —
NAGEJYND 2026-08-28 ✓ c-csi-drift-real-floor —
YAC55J3P 2026-08-28 ✓ c-csi-drift-real-floor —

All exp-csi-static runs in the workbench →

Provenance

Data origin
simulated
Domain
csi
Room layout
fiit-ground-fleet

Data types

  • csi-amplitude
  • per-link-summary